CrossOver 6 / 12 User Manual (v4.0) Calibration and Diagnostics • 7–1
Calibration and Diagnostics
This chapter describes how to check the version of
software on the switcher, copy switcher logs to a
USB, perform calibration and systems tests, as well
as what the error messages reported by the switcher
mean.
Switcher Software Version
The Status menu shows the version number of the
software that is currently running on the control
panel and frame.
To view the current version of software on the
switcher:
1. Press MENU.
2. Press the STATUS Wipe Pattern button.
The current software version (SW Ver) and
reference format is shown on the menu.
Copy Logs to USB
The Copy Logs allows you to store switcher logs
onto a USB. Switcher logs can be used by technical
support to diagnose problems with your switcher.
To copy switcher logs to USB:
1. Insert it into the USB port on the switcher. Wait
5 seconds after inserting the USB drive before
using it.
2. Press MENU > SYSTEM >
NEXT > NEXT.
3. Press the Diag Tests knob.
4. Press NEXT.
5. Press the Copy Logs knob. The logs are
copied to the root directory of the USB.
Calibration
Calibration allows you to reset the limits of the
faders on the control panel and re-center the
positioner with X and Y limits.
To calibrate the positioner and fader:
1. Press MENU > SYSTEM >
NEXT > NEXT.
2. Press the Diag Tests knob.
3. Press NEXT.
4. Press the Calib Reset knob.
5. Move the positioner backwards and forwards
and left to right a few times.
6. Move the fader from one limit to the next a few
times. Do not push the fader hard when it
reaches the limit.
7. Press MENU to save the calibration
information.
Diagnostics
Diagnostics consist of a number of tests that are used
to test the functionality of a number of switcher
functions.
Control Test
The Control Test allows you to test the functionality
of any of the buttons, knobs or fader and positioner
on the control panel.
To test control panel control surfaces:
1. Press MENU > SYSTEM >
NEXT > NEXT.
2. Press the Diag Tests knob.
3. Press the Contrl Test knob. The second line
of the display show the current button, knob,
positioner, or fader being used.
4. Test the button, knob, positioner, and fader you
want to check.
5. Press the MENU and RESET buttons
at the same time to end the test.
MENU
MENU
NEXT
NEXT
NEXT
MENU
NEXT
NEXT
NEXT
MENU
MENU
NEXT
NEXT
MENU